Model Name/ID |
METAL SHARK® GF compact |
Electronics |
Digital signal processor, digital frequency generation, digital balance control, automatic calibration, digital noise filters, integrated flexible control functions |
Input |
2 analog 0…10 V DC (option: 4-20 mA)
8 freely configurable 24 V DC signals, e.g. for reject confirmation |
Output |
2 floating: “error” and “metal”
8 freely configurable 24 V DC signals, e.g. for metal or acoustic alarm |
Inspection Method |
High-frequency magnetic field, multi-channel operation, symmetrical receiver coils |
Metal Detection |
Ferrous, non-ferrous (e.g. aluminium or copper) und stainless steel |
Product Compensation |
Memory for up to 250 products, automatic product compensation, with TeachAssistant |
Enclosure Rating |
IP65 (optionally IP66) |
Environmental Conditions for Controller |
-30°C to +40°C / -22°F to 104°F, UL version: -20°C to +40°C / -4°F to 104°F
rel. humidity 20% up to 90% (non-condensing)
Option: -40°C / -40°F or +55°C / 131°F |
Environmental Conditions for Sensor |
-30°C to +60°C / -22°F to 140°F Option: up to +90° C / 194°F |
Temperature of Goods Inspected |
standard: -30°C up to 55°C / -22°F up to 131°F
option: -40°C / -40°F or up to 120°C / 248°F or up to 180°C / 356°F |
Power Supply |
one phase 110-230 V AC, typ. consumption 20 W (max. 60 W) |
Interface |
RS232, provides documentation according to HACCP- and IFS-standard, USB- or ethernet option |
Maintenance |
Maintenance-free, sensors calibrate themselves |
Diagnostics |
Integrated diagnostic software, automatic self-test |
Infeed and Reject System |
available pipe diameter 100 to 300 mm (4" to 12"), reject available for 100 to 250 mm (4" to 10"), reject types EX-P compact (for powder), EX-S compact (for grain, nuts) |
Stand |
Not applicable |
Flow rate |
100 mm pipe has 20000 l/h (700 cu ft/hr), 300 mm pipe has 165000 l/h (5800 cu ft/hr), for easy flowing product such as dry sugar |
Best Metal Sensitivity |
100 mm pipe has Fe 0.7/Nfe 1.0/SS 1.1 mm, 300 mm pipe has Fe 2.0/Nfe 3.2/SS 4.1 mm only approximate values, depending on with/without ejector, working frequency, etc. |
Product Guidance and Reject System |
FDA-compliant design made of stainless steel and PVDF for all parts in contact with the product, except pipe diameter 300 mm (12") is without FDA-compliant design |